Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Abb S2C-H20L Auxiliary Contact for S200 Mcb
Abb S2C-H20L Auxiliary Contact for S200 Mcb
Brand:
ABB
Model:
S2C-H20L
Image
Image
Product Description

Abb S2C-H20L Auxiliary Contact for S200 Mcb

  • Indication of the position of the device’s contacts. To be mounted on the left side of the MCBs. Suitable for MCBs S 200 series.
  • Product Net Width:8.8 mm
  • Product Net Height:85 mm
  • Product Net Depth / Length:69 mm
  • Product Net Weight:0.055 kg

Technical

  • Function:Auxiliary Contact
  • Suitable For:S200
  • S200M
  • S200P
  • S200S
  • S200 MT
  • S200 MUC
  • S300P
  • Suitable for Product Class:Miniature Circuit Breaker
  • Power Loss:1 W
  • Maximum 1 W
  • Number of Auxiliary Contacts NC:0
  • Number of Auxiliary Contacts NO:2
  • Number of Auxiliary Contacts CO (SPDT):0
  • Accessory Type:Auxiliary Contact
  • Mounting Position:left
  • Environmental
  • RoHS Status:Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
  • RoHS Information:9AKK108468A4564
  • REACH Declaration:9AKK107492A1906
  • Environmental Information:2CDK400571D0201
  • Unit of measurement : Pcs
RM 104.16
Quantity:
EA
Stock:
2 EA in stock
location
In Seller's Warehouse
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
57 Items
auxiliary-contact-img
Rated Current
6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC
Range
TeSys D, TransferPacT, C6-, Tesys, Multi 9
Standard
IEC 60947-3, IEC 60947-5, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1, EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14, 500 V, 400 V
IP Degree of Protection
IP2X conforming to IEC 60529, IP20 conforming to IEC 60529, IP2X, IP20 conforming to EN/IEC 60947-5-1, IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Ambient Air Temperature for Operation
-5…60 °C, -20…50 °C, -35…70 °C, -25…50 °C, -25…60 °C
Ambient Air Temperature for Storage
-60…80 °C, -50…70 °C, -40…70 °C, -40…85 °C, -50…80 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from ABB
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top