Shopping List
Shopping List
MYR - RM
Image
/
/
/
/
Abb AF16-30-10-13 Contactor 3P 7.5KW 1NO 50/60HZ 100-250VAC/DC
Abb AF16-30-10-13 Contactor 3P 7.5KW 1NO 50/60HZ 100-250VAC/DC
Brand:
ABB
Model:
AF16-30-10-13
Image
Image
Product Description

Abb AF16-30-10-13 Contactor 3P 7.5KW 1NO 50/60HZ 100-250VAC/DC

  • Extended Product Type:AF16-30-10-13
  • Product ID:1SBL177001R1310
  • EAN:3471523110632
  • Catalog Description:AF16-30-10-13 100-250V50/60HZ-DC Contactor
  • Long Description:The AF16-30-10-13 is a 3 pole - 690 V IEC or 600 UL contactor with 1 built-in auxiliary contact and screw terminals, controlling motors up to 7.5 kW / 400 V AC (AC-3) or 10 hp / 480 V UL and switching power circuits up to 30 A (AC-1) or 30 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
  • Number of Main Contacts NO:3
  • Number of Main Contacts NC:0
  • Number of Auxiliary Contacts NO:1
  • Number of Auxiliary Contacts NC:0
  • Standards:IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
  • Rated Operational Voltage:Auxiliary Circuit 690 V
  • Main Circuit 690 V
  • Rated Frequency (f):Auxiliary Circuit 50 / 60 Hz
  • Control Circuit 50 / 60 Hz
  • Main Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A
  • acc. to IEC 60947-5-1, Θ = 40 °C 16 A
  • Rated Operational Current AC-1 (Ie):(690 V) 40 °C 30 A
  • (690 V) 60 °C 30 A
  • (690 V) 70 °C 26 A
  • Rated Operational Current AC-3 (Ie):(415 V) 60 °C 18 A
  • (440 V) 60 °C 18 A
  • (500 V) 60 °C 15 A
  • (690 V) 60 °C 10.5 A
  • (380 / 400 V) 60 °C 18 A
  • (220 / 230 / 240 V) 60 °C 18 A
  • Rated Operational Current AC-3e (Ie):(415 V) 60 °C 18 A
  • (440 V) 60 °C 18 A
  • (500 V) 60 °C 15 A
  • (690 V) 60 °C 10.5 A
  • (380 / 400 V) 60 °C 18 A
  • (220 / 230 / 240 V) 60 °C 18 A
  • Rated Operational Power AC-3 (Pe):(400 V) 7.5 kW
  • (415 V) 9 kW
  • (440 V) 9 kW
  • (500 V) 9 kW
  • (690 V) 9 kW
  • (380 / 400 V) 7.5 kW
  • (220 / 230 / 240 V) 4 kW
  • Rated Operational Power AC-3e (Pe):(415 V) 9 kW
  • (440 V) 9 kW
  • (500 V) 9 kW
  • (690 V) 9 kW
  • (380 / 400 V) 7.5 kW
  • (220 / 230 / 240 V) 4 kW
  • Rated Operational Current AC-15 (Ie):(500 V) 2 A
  • (690 V) 2 A
  • (24 / 127 V) 6 A
  • (220 / 240 V) 4 A
  • (400 / 440 V) 3 A
  • Rated Short-time Withstand Current Low Voltage (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A
  • for 0.1 s 140 A
  • for 1 s 100 A
  • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A
  • cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
  • Maximum Electrical Switching Frequency:(AC-1) 600 cycles per hour
  • (AC-15) 1200 cycles per hour
  • (AC-2 / AC-4) 300 cycles per hour
  • (AC-3) 1200 cycles per hour
  • (DC-13) 900 cycles per hour
  • Rated Operational Current DC-1 (Ie):(110 V) 1-Pole, 40 °C 20 A
  • (110 V) 1-Pole, 60 °C 20 A
  • (110 V) 1-Pole, 70 °C 20 A
  • (110 V) 2 Poles in Series, 40 °C 30 A
  • (110 V) 2 Poles in Series, 60 °C 30 A
  • (110 V) 2 Poles in Series, 70 °C 26 A
  • (110 V) 3 Poles in Series, 40 °C 30 A
  • (110 V) 3 Poles in Series, 60 °C 30 A
  • (110 V) 3 Poles in Series, 70 °C 26 A
  • (220 V) 2 Poles in Series, 40 °C 20 A
  • (220 V) 2 Poles in Series, 60 °C 20 A
  • (220 V) 2 Poles in Series, 70 °C 20 A
  • (220 V) 3 Poles in Series, 40 °C 30 A
  • (220 V) 3 Poles in Series, 60 °C 30 A
  • (220 V) 3 Poles in Series, 70 °C 26 A
  • (72 V) 1-Pole, 40 °C 30 A
  • (72 V) 1-Pole, 60 °C 30 A
  • (72 V) 1-Pole, 70 °C 26 A
  • (72 V) 2 Poles in Series, 40 °C 30 A
  • (72 V) 2 Poles in Series, 60 °C 30 A
  • (72 V) 2 Poles in Series, 70 °C 26 A
  • (72 V) 3 Poles in Series, 40 °C 30 A
  • (72 V) 3 Poles in Series, 60 °C 30 A
  • (72 V) 3 Poles in Series, 70 °C 26 A
  • Rated Operational Current DC-3 (Ie):(110 V) 1-Pole, 40 °C 8 A
  • (110 V) 1-Pole, 60 °C 8 A
  • (110 V) 1-Pole, 70 °C 8 A
  • (110 V) 2 Poles in Series, 40 °C 30 A
  • (110 V) 2 Poles in Series, 60 °C 30 A
  • (110 V) 2 Poles in Series, 70 °C 26 A
  • (110 V) 3 Poles in Series, 40 °C 30 A
  • (110 V) 3 Poles in Series, 60 °C 30 A
  • (110 V) 3 Poles in Series, 70 °C 26 A
  • (220 V) 2 Poles in Series, 40 °C 8 A
  • (220 V) 2 Poles in Series, 60 °C 8 A
  • (220 V) 2 Poles in Series, 70 °C 8 A
  • (220 V) 3 Poles in Series, 40 °C 30 A
  • (220 V) 3 Poles in Series, 60 °C 30 A
  • (220 V) 3 Poles in Series, 70 °C 26 A
  • (72 V) 1-Pole, 40 °C 30 A
  • (72 V) 1-Pole, 60 °C 30 A
  • (72 V) 1-Pole, 70 °C 26 A
  • (72 V) 2 Poles in Series, 40 °C 30 A
  • (72 V) 2 Poles in Series, 60 °C 30 A
  • (72 V) 2 Poles in Series, 70 °C 26 A
  • (72 V) 3 Poles in Series, 40 °C 30 A
  • (72 V) 3 Poles in Series, 60 °C 30 A
  • (72 V) 3 Poles in Series, 70 °C 26 A
  • Rated Operational Current DC-5 (Ie):(110 V) 1-Pole, 40 °C 4 A
  • (110 V) 1-Pole, 60 °C 4 A
  • (110 V) 1-Pole, 70 °C 4 A
  • (110 V) 2 Poles in Series, 40 °C 20 A
  • (110 V) 2 Poles in Series, 60 °C 20 A
  • (110 V) 2 Poles in Series, 70 °C 20 A
  • (110 V) 3 Poles in Series, 40 °C 30 A
  • (110 V) 3 Poles in Series, 60 °C 30 A
  • (110 V) 3 Poles in Series, 70 °C 26 A
  • (220 V) 2 Poles in Series, 40 °C 4 A
  • (220 V) 2 Poles in Series, 60 °C 4 A
  • (220 V) 2 Poles in Series, 70 °C 4 A
  • (220 V) 3 Poles in Series, 40 °C 16 A
  • (220 V) 3 Poles in Series, 60 °C 16 A
  • (220 V) 3 Poles in Series, 70 °C 16 A
  • (72 V) 1-Pole, 40 °C 16 A
  • (72 V) 1-Pole, 60 °C 16 A
  • (72 V) 1-Pole, 70 °C 16 A
  • (72 V) 2 Poles in Series, 40 °C 30 A
  • (72 V) 2 Poles in Series, 60 °C 30 A
  • (72 V) 2 Poles in Series, 70 °C 26 A
  • (72 V) 3 Poles in Series, 40 °C 30 A
  • (72 V) 3 Poles in Series, 60 °C 30 A
  • (72 V) 3 Poles in Series, 70 °C 26 A
  • Rated Operational Current DC-13 (Ie):(24 V) 6 A / 144 W
  • (48 V) 2.8 A / 134 W
  • (72 V) 1 A / 72 W
  • (110 V) 0.55 A / 60 W
  • (125 V) 0.55 A / 69 W
  • (220 V) 0.27 A / 60 W
  • (250 V) 0.27 A / 68 W
  • (400 V) 0.15 A / 60 W
  • (500 V) 0.13 A / 65 W
  • (600 V) 0.1 A / 60 W
  • Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 690 V
  • acc. to IEC 60947-5-1 690 V
  • acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):6 kV
  • Maximum Mechanical Switching Frequency:3600 cycles per hour
  • Rated Control Circuit Voltage (Uc):50 Hz 100 ... 250 V
  • 60 Hz 100 ... 250 V
  • DC Operation 100 ... 250 V
  • Operate Time:Between Coil De-energization and NC Contact Closing 13 ... 98 ms
  • Between Coil De-energization and NO Contact Opening 11 ... 95 ms
  • Between Coil Energization and NC Contact Opening 38 ... 90 ms
  • Between Coil Energization and NO Contact Closing 40 ... 95 ms
  • Mounting on DIN Rail:TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
  • TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
  • Mounting by Screws (not supplied):2 x M4 screws placed diagonally
  • Connecting Capacity Main Circuit:Flexible with Ferrule 1/2x 0.75 ... 6 mm²
  • Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²
  • Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
  • Rigid Solid 1/2x 1 ... 4 mm²
  • Rigid Stranded 1/2x 1 ... 6 mm²
  • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
  • Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
  • Rigid Solid 1/2x 1 ... 2.5 mm²
  • Rigid Stranded 1/2x 1 ... 2.5 mm²
  • Connecting Capacity Control Circuit:Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
  • Rigid Solid 1/2x 1 ... 2.5 mm²
  • Rigid Stranded 1/2x 1 ... 2.5 mm²
  • Wire Stripping Length:Auxiliary Circuit 10 mm
  • Control Circuit 10 mm
  • Main Circuit 10 mm
  • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
  • acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
  • Terminal Type:Screw Terminals
  • Unit of Measurement : Pcs
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Contactors from ABB
Source & compare similar products
More from Contactors
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top