Abb AF146-30-11-13 Contactor 3P 75KW 1NO 1NC 50/60HZ 100-250VAC/DC
Abb AF146-30-11-13 Contactor 3P 75KW 1NO 1NC 50/60HZ 100-250VAC/DC
Brand:
ABB
Model:
AF146-30-11-13
Image
Image
Product Description

Abb AF146-30-11-13 Contactor 3P 75KW 1NO 1NC 50/60HZ 100-250VAC/DC

  • Extended Product Type:AF146-30-11-13
  • Product ID:1SFL467001R1311
  • EAN:7320500476994
  • AF146-30-11-13 Contactor
  • The AF146-30-11-13 is a 3 pole - 1000 V IEC or 600 V UL contactor with pre-mounted auxiliary contacts and double clamp, controlling motors up to 75 kW / 400 V AC (AC-3) or 100 hp / 480 V UL and switching power circuits up to 225 A (AC-1) or 200 A UL general use. Thanks to the AF technology, the contactor has a wide control voltage range (100-250 V 50/60 Hz and DC), managing large control voltage variations, reducing panel energy consumptions and ensuring distinct operations in unstable networks. Furthermore, surge protection is built-in, offering a compact solution. AF contactors have a block type design, can be easily extended with add-on auxiliary contact blocks and an additional wide range of accessories.
  • Number of Main Contacts NO:3
  • Number of Main Contacts NC:0
  • Number of Auxiliary Contacts NO:1
  • Number of Auxiliary Contacts NC:1
  • Rated Operational Voltage:Main Circuit 1000 V
  • Rated Frequency (f):Main Circuit 50 / 60 Hz
  • Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 225 A
  • Rated Operational Current AC-1 (Ie):(1000 V) 40 °C 225 A
  • (1000 V) 55 °C 200 A
  • (1000 V) 60 °C 200 A
  • (1000 V) 70 °C 175 A
  • (690 V) 40 °C 225 A
  • (690 V) 55 °C 200 A
  • (690 V) 60 °C 200 A
  • (690 V) 70 °C 175 A
  • Rated Operational Current AC-3 (Ie):(415 V) 55 °C 146 A
  • (440 V) 55 °C 146 A
  • (500 V) 55 °C 130 A
  • (690 V) 55 °C 93 A
  • (1000 V) 55 °C 60 A
  • (380 / 400 V) 55 °C 146 A
  • (220 / 230 / 240 V) 55 °C 146
  • Rated Operational Current AC-3e (Ie):(415 V) 60 °C 146 A
  • (440 V) 60 °C 146 A
  • (500 V) 60 °C 130 A
  • (690 V) 60 °C 93 A
  • (1000 V) 60 °C 54 A
  • (380 / 400 V) 60 °C 146 A
  • (220 / 230 / 240 V) 60 °C 146 A
  • Rated Operational Power AC-3 (Pe):(415 V) 75 kW
  • (440 V) 90 kW
  • (500 V) 90 kW
  • (690 V) 90 kW
  • (1000 V) 75 kW
  • (380 / 400 V) 75 kW
  • (220 / 230 / 240 V) 45 kW
  • Rated Operational Power AC-3e (Pe):(415 V) 75 kW
  • (440 V) 90 kW
  • (500 V) 90 kW
  • (690 V) 90 kW
  • (1000 V) 75 kW
  • (380 / 400 V) 75 kW
  • (220 / 230 / 240 V) 45 kW
  • Rated Breaking Capacity AC-3:8 x Ie AC-3
  • Rated Breaking Capacity AC-3e:8.5 x Ie AC-3e
  • Rated Making Capacity AC-3:10 x Ie AC-3
  • Rated Making Capacity AC-3e:12 x Ie AC-3e
  • Short-Circuit Protective Devices:gG Type Fuses 315 A
  • Rated Short-time Withstand Current Low Voltage (Icw):at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 A
  • at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A
  • Maximum Breaking Capacity:cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 A
  • cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A
  • Maximum Electrical Switching Frequency:(AC-1) 300 cycles per hour
  • (AC-2 / AC-4) 150 cycles per hour
  • (AC-3) 300 cycles per hour
  • Rated Insulation Voltage (Ui):acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • acc. to UL/CSA 600 V
  • Rated Impulse Withstand Voltage (Uimp):Main Circuit 8 kV
  • Mechanical Durability:5 million
  • Maximum Mechanical Switching Frequency:300 cycles per hour
  • Coil Operating Limits:(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
  • Rated Control Circuit Voltage (Uc):50 Hz 100 ... 250 V
  • 60 Hz 100 ... 250 V
  • DC Operation 100 ... 250 V
  • Coil Consumption:Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·A
  • Holding at Max. Rated Control Circuit Voltage 60 Hz 6 V·A
  • Holding at Max. Rated Control Circuit Voltage DC 3 W
  • Pull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·A
  • Pull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·A
  • Pull-in at Max. Rated Control Circuit Voltage DC 135 W
  • Operate Time:Between Coil De-energization and NO Contact Opening 37 ... 47 ms
  • Between Coil Energization and NO Contact Closing 25 ... 55 ms
  • Connecting Capacity Main Circuit:Flexible 1 x 10 ... 70 mm²
  • Rigid Cu-Cable 1 x 10 ... 95 mm²
  • Connecting Capacity Auxiliary Circuit:Flexible with Ferrule 2x 0.75 ... 2.5 mm²
  • Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
  • Flexible 2x0.75 ... 2.5 mm²
  • Solid 2 x 1 ... 4 mm²
  • Stranded 1 x 1 .... 4 mm²
  • Degree of Protection:acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type:Double Clamp
  • Unit of Measurement : Pcs