Taking Lincoln’s Pump Performance and Dependability In A Totally New Direction. The fully integrated P653S pump is an example of Lincoln’s commitment to providing innovative, cost-effective solutions through industry-leading advances in technology. This next-generation, lower-cost pump package can be fitted with one of four reservoir sizes and easily adapts to many applications.
Centro-Matic
System Overview
An air, hydraulic or electric pump automatically develops lubricant pressure through a single supply line to the injectors.
Each injector services one lubrication point and may be accurately adjusted to deliver the precise amount of grease or oil required for each bearing. Both oil and grease injectors are available in various output ranges, in stainless steel and in high-heat models.
Centro-Matic system features
• Extremely lexible
Easy to add or reduce lubrication points
• Adjustability
Injector outputs are adjustable – down to 0.001 in.3 (0,016 cm3)
• System monitoring
Alarm systems are available to monitor pressure, low reservoir level and the low of lubricant at the bearing (System Sentry)
• Capable of pumping long distances at high pressures. More than 300 ft. (91,4 m) with grease, pressures up to 6 000 psi (414 bar) depending on the injector and pump models
• Large number of lubrication points
More than 500 lubrication points (depending on bearing size)
Build-Up Code: P653S-8XLBO-24-1A-AS15
P653S Pump Features
• Integrated pump supplies lubricant to a single-line parallel lubrication system
• Pumps low- and high-viscosity greases including industry standard NLGI grade 2 grease
• Easily interfaces with telematics technology in today’s heavy equipment
• Operating temperature range from -40°F to +158°F (-40°C to +70°C) VDC or 32°F to 122°F (0°C to 50°C) VAC*
• Neutral switch allows mobile equipment to remain idling with pump power on but the the timer is deactivated – allowing manual lubrication functionality.
• All pumps include low-level and system fault alarms
Benefits
• Integration of major system components reduces labor and overall costs
• Simpliies lubrication system design
• Installation time is reduced due to the ”plug-and-play” pump design. Simply mount the pump, connect power and the supply lines and the system is ready for operation.
• Neutral switch ensures lubrication only when the machine is operating – eliminating wasted grease.
P653S Pump Specifications for Grease Applications
Electrical data DC Pumps AC Pumps
Incoming voltage: 19 to 31 VDC 100 to 240 VAC
Maximum current: 10 amps 1.7 amps
Frequency: — 47 to 63 hz
Operating temperature: -40 to +158°F (-40 to +70°C) 32 to 122°F (0 to 50°C)
Minimum pause time: 4 min.
Maximum pause time: 59 hrs. 59 min.
Pause time increments: 1 hr. or 1 min.
Maximum pumping time: 12 min.
Common Electrical Data for DC and AC Pumps
Pump P653S
Operating pressure with:
Pressure switch (ixed): 3,500 psig (240 bar)
Pressure transducer (adj.): 1,400 to 4,600 psig (96 to 317 bar)
End of line pressure switch and transducer
setting (not adj.): 2,500 psig (172 bar)
Number of outlets: 1
Output: 1.5 in3/min (24.6 cm3/min)
Pump Elements
Piston diameter: 7 mm
Number of pumping elements
(connected together): 3
Protection 1P 6K9K
Units | Discount | Unit Price |
---|---|---|