Current
Voltage
Frequency
Power factor
Energy
Active and reactive power
Display Type
Backlit LCD
Standards
IEC 60529
EN 50470-1
UL 61010-1
IEC 62053-24
EN 50470-3
IEC 62053-22:2020
IEC 61557-12:2015
ANSI C12.20
IEC 62053-23:2020
IEC 62052-11:2020
IEC 62052-31:2015
Ambient Air Temperature for Operation
-25…70 °C
Width
96 mm
This spec is not available in the specification table.
Device Short Name
PM5561
This spec is not available in the specification table.
Product or Component Type
Power meter
This spec is not available in the specification table.
Product Name
PowerLogic PM5000
This spec is not available in the specification table.
Depth
72 mm
This spec is not available in the specification table.
Device Application
Multi-tariff
WAGES metering
Gateway
Power monitoring
This spec is not available in the specification table.
Mounting Support
Framework
This spec is not available in the specification table.
Height
96 mm
This spec is not available in the specification table.
Mounting Mode
Flush-mounted
This spec is not available in the specification table.
Accuracy class
Class 0.2S active energy conforming to IEC 62053-22
This spec is not available in the specification table.
Network Frequency
60 Hz
50 Hz
This spec is not available in the specification table.
Sampling rate
128 samples/cycle
This spec is not available in the specification table.
Measurement current
50…10000 mA
This spec is not available in the specification table.
Communication Port Protocol
Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds even/odd or none - 2 wires, insulation 2500 V
JBUS
Modbus TCP/IP at 10/100 Mbit/s, insulation 2500 V
Ethernet Modbus TCP/IP daisy chain
BACnet IP
DNP3 over ethernet
This spec is not available in the specification table.
Communication port support
RS485
ETHERNET
This spec is not available in the specification table.
Number of inputs
4 digital
This spec is not available in the specification table.
Number of outputs
2 digital
This spec is not available in the specification table.
Connections - Terminals
Voltage circuit: screw terminal block4
Control circuit: screw terminal block2
Current transformer: screw terminal block6
RS485 link: screw terminal block4
Digital input: screw terminal block8
Digital output: screw terminal block4
Ethernet network: RJ45 connector2
This spec is not available in the specification table.
Product certifications
CE conforming to IEC 61010-1
CULus conforming to UL 61010-1
MID conforming to EN 50470-1
MID conforming to EN 50470-3
This spec is not available in the specification table.
IP Degree of Protection
IP54 display: conforming to IEC 60529
IP30 rear: conforming to IEC 60529
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % at 50 °C non-condensing
This spec is not available in the specification table.
Ambient Air Temperature for Storage
-40…85 °C
This spec is not available in the specification table.
Operating Altitude
<= 3000 m
This spec is not available in the specification table.
Power quality analysis
up to the 63rd harmonic
This spec is not available in the specification table.
supply voltage
100...300 V DC
90...528 V AC 45...65 Hz
This spec is not available in the specification table.
type of network
3P
3P + N
1P + N
This spec is not available in the specification table.
Maximum power consumption in VA
16 VA at 480 V
This spec is not available in the specification table.
Ride-through time
35 ms 120 V AC typical
129 ms 230 V AC typical
50 ms 125 V DC typical
This spec is not available in the specification table.
Display resolution
128 x 128 pixels
This spec is not available in the specification table.
Analogue input type
Voltage (impedance 5 MOhm)
Current (impedance <= 0.3 mOhm)
This spec is not available in the specification table.
Measurement voltage
20…400 V AC 45...65 Hz between phase and neutral
20…828 V AC 45...65 Hz between phases
This spec is not available in the specification table.
Frequency measurement range
45…65 Hz
This spec is not available in the specification table.
Measurement accuracy
Apparent power +/- 0.5 %
Frequency +/- 0.05 %
Active energy +/- 0.2 %
Reactive energy +/- 1 %
Active power +/- 0.2 %
Voltage +/- 0.1 %
Power factor +/- 0.005
Current +/- 0.15 %
Reactive power +/- 1 %
This spec is not available in the specification table.
data recording
Maintenance logs
Data logs
Alarm logs
Event logs
Min/max of instantaneous values
Time stamping
This spec is not available in the specification table.
Electromagnetic Compatibility
Limits for harmonic current emissions class A conforming to IEC 61000-3-2
Conducted RF disturbances level 3 conforming to IEC 61000-4-6
Magnetic field at power frequency level 4 conforming to IEC 61000-4-8
Conducted and radiated emissions class B conforming to EN 55022
Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3
Electrostatic discharge - test level: 8 kV level 4 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
Surge immunity test level 4 conforming to IEC 61000-4-5
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
This spec is not available in the specification table.
Information displayed
Tariff (8)
This spec is not available in the specification table.
memory capacity
1.1 MB
This spec is not available in the specification table.
Metering type
Measured neutral current
Calculated ground current
This spec is not available in the specification table.
Web services
Alarm notification by e-mail
Web server
Diagnostic via predefined web pages
Real time viewing of data
This spec is not available in the specification table.
Ethernet service
SNMP-Traps
SNTP client
This spec is not available in the specification table.
communication gateway
Ethernet/serial
This spec is not available in the specification table.