Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric LTMEV40FM Extension Module, Tesys T, 4 Inputs, 100 to 240VAC, for Ltmr Controller
Schneider Electric LTMEV40FM Extension Module, Tesys T, 4 Inputs, 100 to 240VAC, for Ltmr Controller
Image
Image
Specifications
infotip-icon
View other Motor Starter dimensions or variations
Please select at least one specification below.
Operating Temperature
-20…60 °C
Standards and Certifications
CSA C22.2 No 14 IACS E10 IEC 60947-4-1 UL 508 EN 60947-4-1
Width
45 mm
Depth
120.7 mm
[Ui] Rated Insulation Voltage
690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508
[Uimp] Rated Impulse Withstand Voltage
4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
Ip Degree Of Protection
IP20
Height
61 mm
Range
TeSys
This spec is not available in the specification table.
Product Name
TeSys T
This spec is not available in the specification table.
Device Short Name
LTME
This spec is not available in the specification table.
Device Application
Equipment monitoring and control
This spec is not available in the specification table.
Connection Pitch
5.08 mm
This spec is not available in the specification table.
Compatibility Code
LTME
This spec is not available in the specification table.
Connections - Terminals
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Ambient Air Temperature For Storage
-40…80 °C
This spec is not available in the specification table.
Operating Altitude
<= 2000 m without derating
This spec is not available in the specification table.
Tightening Torque
Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
This spec is not available in the specification table.
Measurement Accuracy
1 % voltage (100...830 V) 3 % power factor 5 % active and reactive power
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
This spec is not available in the specification table.
Maximum Operating Rate
1800 cyc/h
This spec is not available in the specification table.
Product Certifications
LROS (Lloyds register of shipping) ATEX NOM EAC RMRoS GL UL DNV BV RINA KERI C-Tick CSA CCC ABS
This spec is not available in the specification table.
Protective Treatment
12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068
This spec is not available in the specification table.
Mechanical Robustness
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
This spec is not available in the specification table.
Fire Resistance
650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94
This spec is not available in the specification table.
Range Compatibility
TeSys TeSys T LTMR motor controller
This spec is not available in the specification table.
Supply
Via the controller
This spec is not available in the specification table.
Logic Input Number
4
This spec is not available in the specification table.
Input Current
3.1 mA at 100 V 7.5 mA at 240 V
This spec is not available in the specification table.
Current State 0 Guaranteed
Logic input: 0...40 V and 2...15 mA for 25 ms
This spec is not available in the specification table.
Current State 1 Guaranteed
Logic input: 79...264 V and <= 15 mA for 25 ms
This spec is not available in the specification table.
Maximum Output Switching Frequency
2 Hz
This spec is not available in the specification table.
Contacts Type And Composition
Without
This spec is not available in the specification table.
Metering Type
Imbalance voltage Active power P, P1, P2, P3 Calculated active and reactive energy (+/- W.h, +/- VAR.h) Voltage U21, U32, U13, V1, V2, V3 Reactive power Q, Q1, Q2, Q3 Frequency Power factor
This spec is not available in the specification table.
Product Description


AU $ 914.07
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Starter from SCHNEIDER ELECTRIC
Source & compare similar products
More from Motor Starter
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top