Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric GV4LE25N Motor Circuit Breaker, Tesys GV4, 3P, 25A, Icu 50kA, Magnetic, Everlink Terminals
Schneider Electric GV4LE25N Motor Circuit Breaker, Tesys GV4, 3P, 25A, Icu 50kA, Magnetic, Everlink Terminals
Image
Image
Specifications
infotip-icon
View other Motor Protection Circuit Breakers dimensions or variations
Please select at least one specification below.
Poles
3P
Rated Current
25 A
Colour
Grey (RAL 7016)
Trip Unit Technology
Magnetic Electronic
Control Type
Toggle
Range
TeSys Deca TeSys Deca
[Ui] Rated Insulation Voltage
800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] Rated Impulse Withstand Voltage
8 kV conforming to IEC 60947-2
IP Degree of Protection
IP40 conforming to IEC 60529
Ambient Air Temperature for Operation
-25…70 °C
Ambient Air Temperature for Storage
-50…85 °C
Operating Altitude
5000 m
[Ue] Rated Operational Voltage
690 V AC 50/60 Hz conforming to IEC 60947-2
Breaking Capacity
100 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 15 kA Icu at 525 V AC 50/60 Hz conforming to IEC 60947-2 8 kA Icu at 660...690 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
This spec is not available in the specification table.
Width
81 mm
This spec is not available in the specification table.
Device Short Name
GV4L
This spec is not available in the specification table.
Product Name
TeSys GV4 TeSys Deca
This spec is not available in the specification table.
Depth
116 mm
This spec is not available in the specification table.
Range of Product
TeSys GV4
This spec is not available in the specification table.
Device Application
Motor protection
This spec is not available in the specification table.
Utilisation Category
Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1
This spec is not available in the specification table.
Suitability for Isolation
Yes conforming to IEC 60947-1
This spec is not available in the specification table.
Standards
EN/IEC 60947-4-1 EN/IEC 60947-2
This spec is not available in the specification table.
Connections - Terminals
EverLink BTR screw connectors (top) 1 cable(s) 1.5…70 mm² - solid EverLink BTR screw connectors (top) 1 cable(s) 1.5…50 mm² - flexible EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…95 mm² - solid EverLink BTR screw connectors (bottom) 1 cable(s) 2.5…70 mm² - flexible
This spec is not available in the specification table.
Height
155 mm
This spec is not available in the specification table.
Pollution Degree
3
This spec is not available in the specification table.
Mechanical Durability
40000 cycles
This spec is not available in the specification table.
Electrical Durability
40000 cycles for AC-3 at 440 V In/2 20000 cycles for AC-3 at 440 V In
This spec is not available in the specification table.
Tightening Torque
9 N.m for cable 16…95 mm² 5 N.m for cable 1.5…10 mm²
This spec is not available in the specification table.
Motor Power kW
7.5 kW at 660...690 V AC 50/60 Hz 5.5 kW at 400...415 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz 9 kW at 660...690 V AC 50/60 Hz 11 kW at 660...690 V AC 50/60 Hz 7.5 kW at 400...415 V AC 50/60 Hz 9 kW at 400...415 V AC 50/60 Hz 11 kW at 400...415 V AC 50/60 Hz 9 kW at 500 V AC 50/60 Hz 11 kW at 500 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 15 kW at 660...690 V AC 50/60 Hz 18.5 kW at 660...690 V AC 50/60 Hz
This spec is not available in the specification table.
[Ith] conventional free air thermal current
115 A conforming to IEC 60947-4-1
This spec is not available in the specification table.
Power dissipation per pole
6.1 W
This spec is not available in the specification table.
Maximum operating rate
25 cyc/h
This spec is not available in the specification table.
Product certifications
IEC CCC EAC EU-RO MR
This spec is not available in the specification table.
Climatic withstand
conforming to IACS E10
This spec is not available in the specification table.
Fire resistance
960 °C conforming to IEC 60695-2-11
This spec is not available in the specification table.
Mechanical robustness
Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27
This spec is not available in the specification table.
Magnetic tripping current
150…350 A
This spec is not available in the specification table.
Rated duty
Continuous conforming to IEC 60947-4-1
This spec is not available in the specification table.
IK Degree of Protection
IK07 conforming to IEC 62262
This spec is not available in the specification table.
Operating Position
Any position
This spec is not available in the specification table.
Product Description
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Motor Protection Circuit Breakers from SCHNEIDER ELECTRIC
Source & compare similar products
More from Motor Protection Circuit Breakers
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top