Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric Auxiliary Contact - 1 Oc or 1 Sd or 1 Sde or 1 Sdv 29450
Schneider Electric Auxiliary Contact - 1 Oc or 1 Sd or 1 Sde or 1 Sdv 29450
Image
Image
Technical Data Sheets
Product Description

SCHNEIDER ELECTRIC Auxiliary Contact - 1 Oc or 1 Sd or 1 Sde or 1 Sdv 29450

  • It is a single standard auxiliary contact that provides all the different indications remotely for ComPact NSX, ComPact NS, PowerPact Multistandard and EasyPact CVS circuit breakers. Remote status information are ON/OFF (OF), trip indication (SD) and fault-trip indication (SDE) for all circuit breakers types. The remote status information for trip indication due to an earth fault (SDV) is used for ComPact NSX and PowerPact Multistandard. The contacts are installed in the device in dedicated slots. This auxiliary contact is a common point changeover type contact with 1 normally open contact and 1 normally closed contact. The rated current is 6A and the minimum load is 100mA at 24 VDC for utilization categories are AC12/AC15/DC12/DC14. Screwless connections with spring terminals provide a fast and reliable connection. The section of connected cables is between 0.5 mm² (AWG20) and 1.5 mm² (AWG16). It complies with IEC 60947-5-1 standard.
AU $ 64.01
Quantity:
EA
Stock:
24 EA in stock
location
In Seller's Warehouse
Shop by Specification Table
You can find items with similar specifications from the table below.
Auxiliary Contact
57 Items
auxiliary-contact-img
Rated Current
6 A at 120 V AC-15 3 A at 240 V AC-15 1.8 A at 400 V AC-15 1.5 A at 480 V AC-15 2.8 A at 24 V DC-13 1.4 A at 48 V DC-13 0.55 A at 125 V DC-13 0.27 A at 250 V DC-13 0.15 A at 400 V DC-13, AC-12 6 A at 240 V, AC 50/60 Hz AC-12 3 A at 415 V, AC 50/60 Hz DC-12 2 A at 48 V, DC DC-12 1.5 A at 60 V, DC DC-12 1 A at 130 V, DC DC-12 6 A at 24 V, DC, DC-12 1 A at 130 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC AC-12 3 A at 415 V, AC 50/60 Hz AC-12 6 A at 240 V, AC 50/60 Hz, AC-12 3 A at 380...415 V, AC 50/60 Hz AC-12 6 A at 220...240 V, AC 50/60 Hz DC-12 1 A at 130 V, DC DC-12 1.5 A at 60 V, DC DC-12 2 A at 48 V, DC DC-12 6 A at 24 V, DC
Range
TeSys D, TransferPacT, C6-, Tesys, Multi 9
Standard
IEC 60947-3, IEC 60947-5, EN/IEC 60947-5-1 UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 JIS C8201-5-1, UL 60947-5-1 CSA C22.2 No 60947-5-1 GB/T 14048.5 EN/IEC 60947-5-1, EN/IEC 60947-5-1
[Ui] Rated Insulation Voltage
690 V conforming to IEC 60947-1, 300 V conforming to UL 508 300 V conforming to CSA C22.2 No 14 250 V conforming to IEC 60947-1, 600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14, 500 V, 400 V
IP Degree of Protection
IP2X conforming to IEC 60529, IP20 conforming to IEC 60529, IP2X, IP20 conforming to EN/IEC 60947-5-1, IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529
Ambient Air Temperature for Operation
-5…60 °C, -20…50 °C, -35…70 °C, -25…50 °C, -25…60 °C
Ambient Air Temperature for Storage
-60…80 °C, -50…70 °C, -40…70 °C, -40…85 °C, -50…80 °C
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Auxiliary Contact from SCHNEIDER ELECTRIC
Source & compare similar products
More from Auxiliary Contact
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top