Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric ATV630U55N4 Variable Speed Drive, Altivar Process ATV600, ATV630, 5.5kW, 7.5hp, 380 to 480V, IP21, Ul Type 1
Schneider Electric ATV630U55N4 Variable Speed Drive, Altivar Process ATV600, ATV630, 5.5kW, 7.5hp, 380 to 480V, IP21, Ul Type 1
Image
Image
Image
Image
Image
Image
Image
Image
Specifications
infotip-icon
View other Inverter Drives dimensions or variations
Please select at least one specification below.
Local Signalling
Local diagnostic: 3 LED (mono/dual colour) Embedded communication status: 5 LED (dual colour) Communication module status: 2 LED (dual colour) Presence of voltage: 1 LED (red)
Range of Product
Altivar Process ATV900
Mounting Mode
Wall mount
Accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Standard
UL 508C IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
IP Degree of Protection
IP21
Ambient Air Temperature for Operation
-15…50 °C (without derating) 50…60 °C (with derating factor)
Ambient Air Temperature for Storage
-40…70 °C
Operating Altitude
<= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m
Vibration Resistance
1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
[Us] Rated Supply Voltage
380...480 V - 15...10 %
Switching Frequency
2...16 kHz adjustable 4...16 kHz with derating factor
Noise Level
54.5 dB
Transmission Rate
10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Power Dissipation in W
Natural convection: 30 W at 380 V, switching frequency 4 kHz Forced convection: 60 W at 380 V, switching frequency 4 kHz
Sampling Duration
2 ms +/- 0.5 ms (DI1...DI8) - discrete input 5 ms +/- 1 ms (DI7, DI8) - pulse input 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input 5 ms +/- 1 ms (AQ1, AQ2) - analog output
Continuous Output Current
5.6 A at 4 kHz for normal duty 4 A at 4 kHz for heavy duty
Line Current
4.3 A at 380 V (normal duty) 3.1 A at 380 V (heavy duty) 3.8 A at 480 V (normal duty) 2.9 A at 480 V (heavy duty)
Apparent Power
3.2 kVA at 480 V (normal duty) 2.4 kVA at 480 V (heavy duty)
Maximum Transient Current
6.7 A during 60 s (normal duty) 6 A during 60 s (heavy duty)
Maximum Input Current
4.3 A
Maximum Output Voltage
480 V
Linearity Error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
Width
144 mm
This spec is not available in the specification table.
Product or Component Type
Variable speed drive
This spec is not available in the specification table.
Depth
206 mm
This spec is not available in the specification table.
Device Application
Industrial application
This spec is not available in the specification table.
Network Frequency
50...60 Hz
This spec is not available in the specification table.
Overvoltage Category
III
This spec is not available in the specification table.
Pollution Degree
2
This spec is not available in the specification table.
Relative Humidity
5…95 % without condensation conforming to IEC 60068-2-3
This spec is not available in the specification table.
Marking
CE
This spec is not available in the specification table.
Environmental Characteristic
Chemical pollution resistance class 3C3 conforming to IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to IEC 60721-3-3
This spec is not available in the specification table.
Analog Input Type
AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA/4...20 mA, impedance: 250 Ohm, resolution 12 bits
This spec is not available in the specification table.
Electromagnetic Compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
This spec is not available in the specification table.
Motor Power kW
2.2 kW for normal duty 1.5 kW for heavy duty
This spec is not available in the specification table.
Minimum Switching Current
Relay output R1, R2, R3: 5 mA at 24 V DC
This spec is not available in the specification table.
Insulation Resistance
> 1 MOhm 500 V DC for 1 minute to earth
This spec is not available in the specification table.
Certifications
CSA UL TÜV
This spec is not available in the specification table.
Operating Position
Vertical +/- 10 degree
This spec is not available in the specification table.
Product Specific Application
Process for industrial
This spec is not available in the specification table.
Shock Resistance
15 gn for 11 ms conforming to IEC 60068-2-27
This spec is not available in the specification table.
Protection Type
Thermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
This spec is not available in the specification table.
Connector Type
2 RJ45 1 RJ45
This spec is not available in the specification table.
Product Destination
Synchronous motors Asynchronous motors
This spec is not available in the specification table.
Discrete Input Number
10
This spec is not available in the specification table.
Analogue Input Number
3
This spec is not available in the specification table.
Assembly Style
Enclosed
This spec is not available in the specification table.
Maximum Switching Current
Relay output R1 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 250 V AC Relay output R2, R3 on resistive load, cos phi = 1: 5 A at 30 V DC Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
This spec is not available in the specification table.
Electrical Connection
Control: screw terminal 0.5...1.5 mm²/AWG 20...AWG 16 Line side: screw terminal 2.5...6 mm²/AWG 14...AWG 10 Motor: screw terminal 2.5...6 mm²/AWG 14...AWG 10 DC bus: screw terminal 2.5...6 mm²/AWG 14...AWG 10
This spec is not available in the specification table.
Network Number of Phases
3 phases
This spec is not available in the specification table.
Discrete Input Logic
Positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
This spec is not available in the specification table.
Discrete Output Number
2
This spec is not available in the specification table.
Regulation Loop
Adjustable PID regulator
This spec is not available in the specification table.
Supply
External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
This spec is not available in the specification table.
Maximum Output Frequency
599 Hz
This spec is not available in the specification table.
Physical Interface
Ethernet 2-wire RS 485
This spec is not available in the specification table.
Input Compatibility
DI1...DI8: discrete input level 1 PLC conforming to IEC 61131-2 DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to IEC 61131-2
This spec is not available in the specification table.
Analogue Output Number
2
This spec is not available in the specification table.
Analogue Output Type
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
This spec is not available in the specification table.
EMC Filter
Integrated With EMC plate option
This spec is not available in the specification table.
Method of Access
Slave Modbus TCP
This spec is not available in the specification table.
Communication Port Protocol
Modbus TCP EtherNet/IP Modbus serial
This spec is not available in the specification table.
Exchange Mode
Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
This spec is not available in the specification table.
Variant
Standard version With braking chopper
This spec is not available in the specification table.
Degree of Protection
UL type 1
This spec is not available in the specification table.
Option Module
Slot A: communication module for Profibus DP V1 Slot A: communication module for PROFINET Slot A: communication module for DeviceNet Slot A: communication module for EtherCAT Slot A: communication module for CANopen daisy chain RJ45 Slot A: communication module for CANopen SUB-D 9 Slot A: communication module for CANopen screw terminals Slot A/slot B/slot C: digital and analog I/O extension module Slot A/slot B/slot C: output relay extension module Slot B: 5/12 V digital encoder interface module Slot B: analog encoder interface module Slot B: resolver encoder interface module communication module for Ethernet Powerlink
This spec is not available in the specification table.
Asynchronous Motor Control Profile
Constant torque standard Optimized torque mode Variable torque standard
This spec is not available in the specification table.
Synchronous Motor Control Profile
Permanent magnet motor Synchronous reluctance motor
This spec is not available in the specification table.
Nominal Switching Frequency
4 kHz
This spec is not available in the specification table.
Prospective Line Isc
50 kA
This spec is not available in the specification table.
Discrete Input Type
DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI7, DI8 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
This spec is not available in the specification table.
Discrete Output Type
Logic output DQ+ 0…1 kHz <= 30 V DC 100 mA Programmable as pulse output DQ+ 0…30 kHz <= 30 V DC 20 mA Logic output DQ- 0…1 kHz <= 30 V DC 100 mA
This spec is not available in the specification table.
Relay Output Number
3
This spec is not available in the specification table.
Relay Output Type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 1000000 cycles Configurable relay logic R3: sequence relay NO electrical durability 1000000 cycles
This spec is not available in the specification table.
Transmission Frame
RTU
This spec is not available in the specification table.
Number of Addresses
1…247 for Modbus serial
This spec is not available in the specification table.
Data Format
8 bits, configurable odd, even or no parity for Modbus serial
This spec is not available in the specification table.
Type of Polarization
No impedance for Modbus serial
This spec is not available in the specification table.
4 Quadrant Operation Possible
True
This spec is not available in the specification table.
Acceleration and Deceleration Ramps
Linear adjustable separately from 0.01...9999 s
This spec is not available in the specification table.
Motor Slip Compensation
Can be suppressed Not available in permanent magnet motor law Adjustable Automatic whatever the load
This spec is not available in the specification table.
Braking to Standstill
By DC injection
This spec is not available in the specification table.
Brake Chopper Integrated
True
This spec is not available in the specification table.
Relative Symmetric Network Frequency Tolerance
5 %
This spec is not available in the specification table.
Base Load Current at High Overload
4.0 A
This spec is not available in the specification table.
Base Load Current at Low Overload
5.6 A
This spec is not available in the specification table.
With Safety Function Safely Limited Speed (SLS)
True
This spec is not available in the specification table.
With Safety Function Safe Brake Management (SBC/SBT)
True
This spec is not available in the specification table.
With Safety Function Safe Operating Stop (SOS)
False
This spec is not available in the specification table.
With Safety function Safe Position (SP)
False
This spec is not available in the specification table.
With Safety Function Safe Programmable Logic
False
This spec is not available in the specification table.
With Safety Function Safe Speed Monitor (SSM)
False
This spec is not available in the specification table.
With Safety Function Safe Stop 1 (SS1)
True
This spec is not available in the specification table.
With sft fct Safe Stop 2 (SS2)
False
This spec is not available in the specification table.
With Safety Function Safe Torque Off (STO)
True
This spec is not available in the specification table.
With Safety Function Safely Limited Position (SLP)
False
This spec is not available in the specification table.
With Safety Function Safe Direction (SDI)
False
This spec is not available in the specification table.
Refresh Time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
This spec is not available in the specification table.
Isolation
Between power and control terminals
This spec is not available in the specification table.
Maximum THDI
<48 % full load conforming to IEC 61000-3-12
This spec is not available in the specification table.
Environmental Class (During Operation)
Class 3C3 according to IEC 60721-3-3 Class 3S3 according to IEC 60721-3-3
This spec is not available in the specification table.
Maximum Acceleration Under Shock Impact (During Operation)
150 m/s² at 11 ms
This spec is not available in the specification table.
Maximum Acceleration Under Vibrational Stress (During Operation)
10 m/s² at 13...200 Hz
This spec is not available in the specification table.
Maximum Deflection Under Vibratory Load (During Operation)
1.5 mm at 2...13 Hz
This spec is not available in the specification table.
Permitted Relative Humidity (During Operation)
Class 3K5 according to EN 60721-3
This spec is not available in the specification table.
Volume of Cooling Air
38 m3/h
This spec is not available in the specification table.
Ambient Air Transport Temperature
-40…70 °C
This spec is not available in the specification table.
Product Description
AU $ 2,837.44
Quantity:
EA
This item is sold by
Image
Schneider Electric
0
Shop by Specification Table
You can find items with similar specifications from the table below.
Inverter Drives
259 Items
inverter-drives-img
Local Signalling
3 LEDs for local diagnostic 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, 1 LED (red) for DC bus energized, 3 LEDs (dual colour) for embedded communication status 4 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage 3 LEDs for local diagnostic, 2 LEDs for local diagnostic 1 LED (yellow) for embedded communication status 2 LEDs (dual colour) for communication module status 1 LED (red) for presence of voltage, Local diagnostic: 3 LED (mono/dual colour) Embedded communication status: 5 LED (dual colour) Communication module status: 2 LED (dual colour) Presence of voltage: 1 LED (red)
Range of Product
Altivar 212, Easy Altivar 610, Altivar 12, Altivar Machine ATV320, Altivar Process ATV600
Mounting Mode
Cabinet mount, Wall Mount, DIN Rail, Cabinet Mount, Panel Mount
Standard
CE, CSA, CE, UL, CE, CSA, UL, ATEX, CE, CSA, cUL, EAC, EN 954-1, EN ISO 13849-1, EN ISO 13849-2, IEC 60204-1, IEC 6100, IEC 61158, IEC 61508, IEC 61784, IEC/EN 60721, TUV, UL 508C, EN/IEC 61800-3 Environment 1 Category C2, EN/IEC 61800-3 Environment 2 Category C3, EN/IEC 61800-5-1, EN/IEC 61800-6, IEC 60721-3, IEC 61000-3-12, IEC 61508, UL508C
IP Degree of Protection
IP20, IP21, IP41, IP00, IP20, IP65, IP54, IP55
Ambient Air Temperature for Operation
-10…50 °C without derating 50…60 °C with current derating 2.2 % per °C, -10…50 °C without derating 50…60 °C with derating factor, 40…50 °C (with derating factor) -15…40 °C (without derating), -15…50 °C (without derating) 50…60 °C (with derating factor), -10…40 °C (without derating) 40…60 °C (with derating factor)
Operating Altitude
<= 3000 m with current derating above 1000m, 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating, <= 1000 m without derating 1000...4800 m with current derating 1 % per 100 m, <= 1000 m without derating 1000...3000 m with current derating 1 % per 100 m, > 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Inverter Drives from SCHNEIDER ELECTRIC
Source & compare similar products
More from Inverter Drives
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top