Shopping List
Shopping List
AUD - AU$
Image
/
/
/
/
Schneider Electric A9D55604 Residual Current Breaker With Overcurrent Protection (rcbo), Acti9 Idpn N Vigi, 1P+N, 4A, B Curve, 6000A, Ac Type, 30mA
Schneider Electric A9D55604 Residual Current Breaker With Overcurrent Protection (rcbo), Acti9 Idpn N Vigi, 1P+N, 4A, B Curve, 6000A, Ac Type, 30mA
Image
Image
Technical Data Sheets
Product Description

SCHNEIDER ELECTRIC Residual Current Breaker With Overcurrent Protection (rcbo), Acti9 Idpn N Vigi, 1P+N, 4A, B Curve, 6000A, Ac Type, 30mA A9D55604

  • This Acti9 iDPN Vigi is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+N circuit breaker with 1 protected pole, 4A In rated current and B tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 6000A according EN/IEC 61009-2-1 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. Its earth fault indicator on front face allows quick identification of the type of default. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. This product is compliant with EN/IEC 61009-2-1 standard. It has an electrical endurance going up to 20000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product color is white (RAL9003). The dimensions are (W) 36mm x (H) 85mm x (D) 73mm. The weight is 125g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -5°C to 60°C. The storage temperature is from -40°C to 85°C.
  • Range:Acti9
  • Product name:Acti9 iDPN Vigi
  • Product or component type:Residual current breaker with overcurrent protection (RCBO)
  • Device short name:IDPN N Vigi
  • Device application:Distribution
  • Poles description:1P + N
  • Number of protected poles:1
  • Neutral position:Left
  • [In] rated current:4 A
  • Network type:AC
  • Trip unit technology:Thermal-magnetic
  • Curve code:B
  • Earth-leakage sensitivity:30 mA
  • Earth-leakage protection time delay:Instantaneous
  • Earth-leakage protection class:Type AC
  • Breaking capacity:6000 A Icn at 220...240 V AC 50 Hz conforming to EN/IEC 61009-2-1
  • Suitability for isolation:Yes conforming to EN/IEC 60947-2
AU $ 193.95
Image
Lead time of 60 working days required.
Item will be ready to dispatch within the lead time specified.
Quantity:
EA
Highly Matched Items
View items that have the same or are a close match to the specifications of this item
Residual current devices - RCDs from SCHNEIDER ELECTRIC
Source & compare similar products
More from Residual current devices - RCDs
Expand your search with a wider selection
Recently Viewed Products
Compare & Refer to previously viewed items
Image
Top