Introduction of voltage input protection functionality
This functionality keeps errors in instrument configuration from resulting in an electrical accident. Even if the instrument’s rotary switch is mistakenly set to the resistance function when attempting to measure voltage, placing the probes in contact with the circuit under measurement will not cause a tripped circuit breaker or electrical arcing.
Pocket DMM that Prevents False Circuit Breaker Trips using Proprietary Technology.
The Hioki DT4200 Digital Multimeter Series consists of a diverse array of meters ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The Hioki DT4223 is a pocket-sized digital multimeter featuring an innovating circuit-breaker false trip prevention function to enhance testing safety and a built-in voltage detector, ideal for electrical inspections.
CAT IV 300 V, CAT III 600 V
Key Features
Achieving a high level of safety in a compact body and lightweight design
Circuit breaker false trip prevention function helps avoid accidents resulting from breakers that mistakenly trip due to incorrect input
Resistance measurement and voltage detection function (DT4223)
Robust design capable of withstanding a drop from a height of 1 m
Test leads conveniently wrap around the back
±0.5% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics
Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms)
Broad -10 (14°F) to 65°C (149°F) operating temperature range
Display backlight
Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)
Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
DC Voltage 600.0 mV to 600.0 V, 4 ranges, Basic accuracy: ±0.5 % rdg. ±5 dgt.
AC Voltage 6.000 V to 600.0 V, 3 ranges, Frequency characteristics: 40 Hz - 1 kHz
Basic accuracy 40 - 500 Hz : ±1.0 % rdg. ±3 dgt. (True RMS, crest factor 3)
Resistance 600.0 Ω to 60.00 MΩ, 6 ranges
Basic accuracy: ±0.9 % rdg. ±5 dgt.
C (capacitance) N/A
Frequency AC V measurement: 99.99 Hz (5 Hz or more) to 9.999 kHz, 3 ranges
Basic accuracy: ±0.1 % rdg. ±2 dgt.
Continuity check Continuity threshold [ON]: 25 Ω or less (buzzer sound), [OFF]: 245 Ω or more Response time: 0.5 ms or more
Diode test N/A
Voltage detection 80 V to 600 V AC
Other functions Circuit breaker false trip prevention function, Filter function, Display value hold, Relative display, Auto-power save
Display Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph
Display refresh rates 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s )
Power supply LR03 alkaline batteries ×4, Continuous use: 35 hours (backlight OFF)
Dimensions and mass 72 mm (2.83 in)W × 149 mm (5.87 in)H× 38 mm (1.50 in)D,190 g (6.7 oz) (including batteries and holster)
Accessories Test lead DT4911 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×1